Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
3.
Europace ; 23(9): 1493-1501, 2021 09 08.
Article in English | MEDLINE | ID: covidwho-1254660

ABSTRACT

AIMS: The aim of this study is to determine the association between the coronavirus disease 2019 (COVID-19) pandemic and atrial fibrillation (AF) occurrence in individuals with cardiac implantable electronic devices (CIEDs). METHOD AND RESULTS: Multi-centre, observational, cohort study over a 100-day period during the COVID-19 pandemic (COVID-19) in the USA. Remote monitoring was used to assess AF episodes in patients with a CIED (pacemaker or defibrillator; 20 centres, 13 states). For comparison, the identical 100-day period in 2019 was used (Control). The primary outcomes were the AF burden during the COVID-19 pandemic, and the association of the pandemic with AF occurrence, as compared with 1 year prior. The secondary outcome was the association of AF occurrence with per-state COVID-19 prevalence. During COVID-19, 10 346 CIEDs with an atrial lead were monitored. There were 16 570 AF episodes of ≥6 min transmitted (16 events per 1000 patient days) with a significant increase in proportion of patients with AF episodes in high COVID-19 prevalence states compared with low prevalence states [odds ratio 1.34, 95% confidence interval (CI) 1.21-1.48, P < 0.001]. There were significantly more AF episodes during COVID-19 compared with Control [incident rate ratio (IRR) 1.33, 95% CI 1.25-1.40, P < 0.001]. This relationship persisted for AF episodes ≥1 h (IRR 1.65, 95% CI 1.53-1.79, P < 0.001) and ≥6 h (IRR 1.54, 95% CI 1.38-1.73, P < 0.001). CONCLUSION: During the first 100 days of COVID-19, a 33% increase in AF episodes occurred with a 34% increase in the proportion of patients with AF episodes observed in states with higher COVID-19 prevalence. These findings suggest a possible association between pandemic-associated social disruptions and AF in patients with CIEDs. CLINICAL TRIAL REGISTRATION: Australian New Zealand Clinical Trial Registry: ACTRN12620000692932.


Subject(s)
Atrial Fibrillation , COVID-19 , Defibrillators, Implantable , Atrial Fibrillation/diagnosis , Atrial Fibrillation/epidemiology , Australia , Cohort Studies , Humans , Pandemics , SARS-CoV-2
4.
Am Heart J ; 235: 158-162, 2021 05.
Article in English | MEDLINE | ID: covidwho-1139418

ABSTRACT

The WiSE system is a novel, leadless endocardial system that can provide cardiac resynchronization therapy in patients who cannot be treated with a conventional epicardial left ventricular lead. Safety and efficacy were being evaluated in the pivotal, randomized, double-blind SOLVE-CRT Trial (Stimulation of the Left Ventricular Endocardium for Cardiac Resynchronization Therapy.) The trial was initiated in 2018; however, patient enrollment was significantly impacted by the COVID-19 pandemic necessitating a change in design. This article describes the revised trial and the scientific rationale for the specific changes in the protocol.


Subject(s)
COVID-19/epidemiology , Cardiac Resynchronization Therapy/methods , Endocardium , Heart Failure/therapy , Pandemics , Cardiac Resynchronization Therapy/adverse effects , Double-Blind Method , Humans , Prospective Studies , Sample Size , Time Factors , Treatment Outcome , Ventricular Function, Left
5.
Eur Heart J ; 42(5): 520-528, 2021 02 01.
Article in English | MEDLINE | ID: covidwho-1104867

ABSTRACT

AIMS: Our objective was to determine the ventricular arrhythmia burden in implantable cardioverter-defibrillator (ICD) patients during COVID-19. METHODS AND RESULTS: In this multicentre, observational, cohort study over a 100-day period during the COVID-19 pandemic in the USA, we assessed ventricular arrhythmias in ICD patients from 20 centres in 13 states, via remote monitoring. Comparison was via a 100-day control period (late 2019) and seasonal control period (early 2019). The primary outcome was the impact of COVID-19 on ventricular arrhythmia burden. The secondary outcome was correlation with COVID-19 incidence. During the COVID-19 period, 5963 ICD patients underwent remote monitoring, with 16 942 episodes of treated ventricular arrhythmias (2.8 events per 100 patient-days). Ventricular arrhythmia burden progressively declined during COVID-19 (P < 0.001). The proportion of patients with ventricular arrhythmias amongst the high COVID-19 incidence states was significantly reduced compared with those in low incidence states [odds ratio 0.61, 95% confidence interval (CI) 0.54-0.69, P < 0.001]. Comparing patients remotely monitored during both COVID-19 and control periods (n = 2458), significantly fewer ventricular arrhythmias occurred during COVID-19 [incident rate ratio (IRR) 0.68, 95% CI 0.58-0.79, P < 0.001]. This difference persisted when comparing the 1719 patients monitored during both the COVID-19 and seasonal control periods (IRR 0.69, 95% CI 0.56-0.85, P < 0.001). CONCLUSIONS: During COVID-19, there was a 32% reduction in ventricular arrhythmias needing device therapies, coinciding with measures of social isolation. There was a 39% reduction in the proportion of patients with ventricular arrhythmias in states with higher COVID-19 incidence. These findings highlight the potential role of real-life stressors in ventricular arrhythmia burden in individuals with ICDs. TRIAL REGISTRATION: Australian New Zealand Clinical Trial Registry; URL: https://www.anzctr.org.au/; Unique Identifier: ACTRN12620000641998.


Subject(s)
Arrhythmias, Cardiac/epidemiology , COVID-19 , Defibrillators, Implantable , Ventricular Fibrillation/epidemiology , Adult , Aged , Arrhythmias, Cardiac/etiology , Arrhythmias, Cardiac/therapy , COVID-19/epidemiology , COVID-19/prevention & control , Cost of Illness , Female , Humans , Incidence , Logistic Models , Male , Middle Aged , Monitoring, Physiologic , Pandemics , Physical Distancing , Protective Factors , Registries , Risk Factors , Stress, Psychological , Telemedicine , United States/epidemiology , Ventricular Fibrillation/etiology , Ventricular Fibrillation/therapy
6.
Heart Lung Circ ; 29(6): e57-e68, 2020 Jun.
Article in English | MEDLINE | ID: covidwho-383246

ABSTRACT

The COVID-19 pandemic poses a significant stress on health resources in Australia. The Heart Rhythm Council of the Cardiac Society of Australia and New Zealand aims to provide a framework for efficient resource utilisation balanced with competing risks when appropriately treating patients with cardiac arrhythmias. This document provides practical recommendations for the electrophysiology (EP) and cardiac implantable electronic devices (CIED) services in Australia. The document will be updated regularly as new evidence and knowledge is gained with time.


Subject(s)
Betacoronavirus , Coronavirus Infections , Defibrillators, Implantable , Electrophysiologic Techniques, Cardiac , Pandemics , Pneumonia, Viral , Australia/epidemiology , COVID-19 , Coronavirus Infections/epidemiology , Coronavirus Infections/physiopathology , Coronavirus Infections/therapy , Humans , Pneumonia, Viral/epidemiology , Pneumonia, Viral/physiopathology , Pneumonia, Viral/therapy , SARS-CoV-2
SELECTION OF CITATIONS
SEARCH DETAIL